Skip to main content
Version: 2.6

BALLUFF BIS-V Driver Configuration

Plugin Configuration

The plugin configuration file is named settings.json located in <install directory>\Config\HumanOS.UHAL.BalluffBisV\. It contains all global settings of the plugin.

See Generic Plugin Configuration for more details.

Device Information File

The device information file is used to configure the access to the BALLUFF BIS-V devices. It contains:

  • Id: unique device id (GUID), which MUST match the device license id.
  • DriverId: ED53B0F7-0D3A-4B82-A9F6-191B0DD47EA5
  • Address: connection address
  • Data Access
  • Commands

See Device Information Model for more details.

Connection Address

The connection to Balluff is realized with TCP/IP.

NameTypeProtocolAddressDefault Port
YOUR_DEVICEBIS-VTCP/IPYOUR_IP_ADDRESS10001
NOTE

Check the BIS-V manual to setup the IP address and ports on the BALLUFF device. The preset address is typically 192.168.72.223 on port 10001.

The address field requires IP address and port of the device.

Example:

{
"Id": "974f33ad-38e8-4d82-b3a4-37b22869651d",
"Name": "Balluff-BIS-V",
"DriverId": "ED53B0F7-0D3A-4B82-A9F6-191B0DD47EA5",
"Address": "10.197.12.50:10001",
...
}