Sinumerik Driver Configuration
Plugin Configuration
The plugin configuration file is named settings.json
located in <install directory>\Config\HumanOS.UHAL.SinumerikControl\
. It contains all global settings of the plugin.
See Generic Plugin Configuration for more details.
Device Information File
The device information file is used to configure the access to the Sinumerik controls. It contains:
Id
: unique device id (GUID), which MUST match the device license id.DriverId
:B657332C-A383-47EE-BEDD-6156AF9C9083
Address
: Connection address- Data Access
See Device Information Model for more details.
Connection Address
The Sinumerik Driver needs an Endpoint specification. Use:
s840d.sl://192.168.0.80
to connect to a Sinumerik 840D SolutionLines840d.pl://192.168.0.80
to connect to a Sinumerik 840D PowerLine
To use a different port instead of 102:
s840d.pl://192.168.0.80:1391
to connect to a Sinumerik 840D PowerLine through port 1391
If the MPI/profibus address differs from the standard setting use following parameters:
s840d.pl://192.168.0.80?nck-mpi=13&plc-rack=0&plc-slot=13
to setnck-mpi
address to 13plc-rack
to 0 (optional)plc slot
to 13 (optional)
Further information about connectivity, see chapter Sinumerik Connectivity.
Trouble shooting connection failures, see chapter Troubleshooting.
Property TcpTimeout
Network Timeout property in Milliseconds, default is 5s. Example 10s:
{
"Name": "TcpTimeout",
"Value": 10000,
"DataType": "System.Int32"
}